Bid Solicitation: BD-23-1202-COCC1-COCC1-97655
Header Information
Bid Number:
BD-23-1202-COCC1-COCC1-97655
Description:
IFB 2024-4 PROVIDE & INSTALL SMOKE DETECTORS
Bid Opening Date:
02/29/2024 11:00:00 AM
Purchaser:
Rita Brousseau
Organization:
Lowell Housing Authority
Department:
COCC1 - Finance & Procurement
Location:
COCC1 - Finance & Procurement
Fiscal Year:
23
Type Code:
NS - Non-Statewide Solicitation
Allow Electronic Quote:
No
Alternate Id:
Required Date:
Available Date :
01/29/2024 10:42:50 AM
Info Contact:
Rita V. Brousseau, Chief Procurement Officer, rbrousseau@lhma.org
Bid Type:
OPEN
Informal Bid Flag:
No
Purchase Method:
Open Market
Pre Bid Conference:
NONE
Bulletin Desc:
LHA is seeking contractors interested in providing and installing battery-operated smoke detectors in bedrooms identified by the Authority.
Ship-to Address:
Rita V. Brousseau
350 Moody Street
Lowell, MA 01854
US
Email: rbrousseau@lhma.org
Phone: (978)364-5341
FAX: (978)937-5758
Bill-to Address:
B OKeefe
PO Box 60
Lowell, MA 01853-0060
US
Email: bokeefe@lhma.org
Phone: (978)364-5310
FAX: (978)937-3725
Print Format:
Bid Print
File Attachments:
HUD-5369-b-Instructions-to-offerors-NONCONSTRUCTION.pdf
Table 5.1.pdf
LHA Code of Ethics.pdf
PO Reservation of Rights 2017
Form Attachments:
Required Quote Attachments
Item Information
Item # 1: ( 72-13 - 00 )
Scope of Work: Contractor shall be responsible for providing and installing new photoelectric battery-operated smoke detectors in every bedroom at properties throughout the agency in accordance with Building Code and Federal HUD Regulations. There are approximately 797 wood ceilings and 1,664 concrete ceilings, see table below for bedroom breakdown. Smoke alarm will be installed on ceilings and must be 18 inches from the wall and 18 inches from the doorway. Smoke alarm will be installed at least 10 feet from a cooking appliance. Smoke alarm should not: - Be installed near windows, doors, or ducts where drafts might interfere with their operation. Installation inside each bedroom; - Within 21 feet of any door to a bedroom measured along a path of travel; and - Where a smoke detector installed outside a bedroom is separated from an adjacent living area by a door. Smoke detectors offered by the bidder shall have 10-Year sealed lithium battery, voice notifications, test button, and end of unit life alerts. The authority reserves the right to determine whether the smoke detectors offered are acceptable.
U N S P S C Code:
72-13-00
General building construction
Qty
Unit Cost
UOM
Total Discount Amt.
Total Cost
1.0
EA - Each